MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4

VERSION ATTRIBUTES:
DIAGNOSTIC MODE:
Troubles Associated with the Surface Burners:
| PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
| UNIT BEEPS WHEN ANY AREA OF THE ECH IS TOUCHED | Defective ground between ECH and unit | Check continuity using ohm meter. Place leads on ECH assembly and the unit. Push the ECH open and closed while performing continuity checks. No reading, go to next possible cause |
| Spring on ECH binding on mounting bracket and housing | Re-center spring in-between bushings | |
| Broken spring on ECH mounting bracket | Replace ECH |